Jul 11, 2017 · HPLC prep using a stacked syringe filter. Syringe filtration often involves aspirating the sample, fitting a particle filter, and filtering into an autosampler vial. The vial is finally capped and transferred to an autosampler. This filtration process can be repeated dozens of time a day, depending on your laboratory workflow and HPLC capacity.
Overview of Non-Sterile Millex® Syringe Filters with Hydrophilic PTFE. • Lowest extractables, optimizing background levels of sensitive analyses like UHPLC and LC-MS. • Filtration of protein-containing solutions, and aqueous or organic solutions. • Available in 0.20 µm and 0.45 µm pore sizes and three diameters to suit your application
Minisart® Syringe Filter, Surfactant-free Cellulose Acetate (SFCA), Pore Size 0.8 µm, Gamma irradiated, Female Luer Lock, Male Luer Lock, Pack Size 50 Added to Shopping Cart Minisart ® NML with surfactant-free cellulose acetate (SFCA) is the best choice for all aqueous solutions and oils with a pH of 4 - 8.
Millex® Syringe filters set the standard for reliable small volume filtration (1 mL to 200 mL). Available in 4, 13, 25, 33, and 50 mm diameters. Minimal hold-up volume for less sample loss o f small volumes and are ideal for solutions such as antibiotics and tissue culture additives. Their unsurpassed quality and consistency of results has led
PerkinElmer. Clear PTFE (Hydrophobic) Syringe Filters, 0.45 µm, 4 mm (200/Pack) have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation. The pure polypropylene housings are.
FilTrex , " Syringe filters-Combined " , The prefilter ( PP membrane 1.0 micron ) is used with normal syringe filter to solve the problem of sample with a high load of particulate or highly viscosity solutions. The PP membrane prefilter removes coarse particles before blockage of the fine main membrane. This is the better filtration efficiency with lower back pressure, easy filtration with high yields of filtrate.
Membrane filters and devices from MilliporeSigma have been used by life sciences researchers, medical schools, hospitals, dialysis centers and many industries to separate molecular components of fluid samples for decades. For a detailed introduction into our membrane technology, access our membrane resource center and the link below.
N ylon 66 membrane syringe filter A vailable in 4mm, 13mm, 25mm 0.2µm SYNN N A 0.45µm SYGN Nylon 66 membrane syringe filter with pre-filter Available in 13mm, 25mm 0.2µm SYGN Nylon 66 membrane syringe filter with pre-filter Available in 13mm, 25mm 0.45µm SYTG PTFE membrane syringe filter with pre-filter Available in 13mm, 25mm 0.2µm SYTG
Syringe filters are ideal for filtering the sample solution before injection. These are usually membrane filters made of appropriate materials. They are also available as glass fiber filters or as membrane filters with glass fiber pre-filters in cases where a glass fiber filter is required in front of the membrane filter.
Puradisc syringe filters for routine syringe filtration. Puradisc syringe filters cater to a wide variety of sample types and applications, including capillary electrophoresis, biological preparations, protein filtration, and UV spectroscopy sample preparation. Different Puradisc membrane media support diverse chemical solvents and compounds
Pre-filter N N Selected membranes Titan3 Syringe filter unit specification Target2 Syringe filter unit specification Syringe filter membrane selection The following is a general guide when selecting the appropriate membrane for your application. The following should be considered: 1 3 4 Membrane compatibility with sample type and technique
Captiva Premium Syringe Filters Premium Syringe Filters Membrane Diameter / Pore size 4 mm 15 mm 25 mm (* 28 mm) 0.2 µm 0.45 µm 0.2 µm 0.45 µm 0.2 µm 0.45 µm PTFE ♦ ♦ ♦ ♦ ♦ ♦ Nylon ♦ ♦ ♦ ♦ PES ♦ ♦ ♦ ♦ ♦ ♦ Regenerated Cellulose ♦ ♦ ♦ ♦ ♦ ♦ Cellulose Acetate ♦ ♦
MS ® syringe filters are simply quality filters, well packaged, and offered at a fair and competitive price. Typical applications are clarification, sterile filtration, sample preparation, sterile venting and medical applications. The syringe filters are available in many different pore sizes and with several hydrophilic or hydrophobic membrane materials.ISO9000 certified manufacturing is carried out to the highest standards, in certified clean room conditions, using the latest
Membrane Solutions provide lab filtration products, such as membrane filter, syringe filter ,for essential separation and purification processes and help scientists anticipate and avoid problems in their downstream analyses by finding the optimum sample preparation method.
Nov 24, 2018 · Membrane Solutions Syringe Filter has a variety of materials and sizes which are adapt to most of applications for laboratories. There are 2 basis type: hydropholic and hydrophilic The production is followed certificate ISO 9000, 14001 which has clean, sterile environment.