12x32mm vial format Superior quality 33 expansion borosilicate clear glass Type 1, Class A or 51A amber glass Uniformly flat bottom for security with inserts I-D vials feature write-on patch with graduations at 0.5, 1.0 and 1.5mL Target ColorBand™ crimp top vials feature color-coded
Basic Supply Kit (2713N15) contains 10 ml syringes (6/ea), 23/26 gauge needles, 4 ml vials with diffusion caps (144/pk), 2 ml automatic sampler vials with screw caps (1,000/pk), GC septa (25/pk), and vial racks (5/pk).Basic Supply Kit Contains 10 ml syringes
Jan 24, 2013 · Aliquot 10 mL WS into 1-mL amber-color crimp-cap GC vials with 300 uL insert, wrap with PTFE tape and store at 4°C. Surrogate Mixtures (200 ug/mL Acid and 100 ug/mL B/N) 1. Add 1mL of each Acid (Restek #31063) and B/N (Restek #31062) source standard into a 50mL volumetric flask, top to the marker with dichloromethane. Cap and invert to mix. 2.
Analytical Chemistry Restek (98) CHROMACOL (87) ... Description: Standard glass or plastic vials for GC and HPLC, micro-inserts, closures and kits. Can be used ...
Products Often Purchased with 10 mL, 20 mm Headspace Crimp-Top Vials, Flat Bottom, Clear, 100-pk. Vial Storage Rack for 6, 10, or 20mL Headspace Vials, 36 Vial Capacity, Polypropylene, ea. 20mm Magnetic Crimp Cap w/PTFE/Silicone Septum (tan/white) with 5mm Hole, 100-pk.
Florisil Cartridge Quality Control Standard Mixture, Restek Florisil Cartridge Quality Control Standard Mixture Chemicals:Standards:Quality Control and Proficiency Samples
Description: Large, economical packs of Restek Poly Crimp seal caps are available for easy application onto any crimp-top vial. ,10059-158PK,10854-050PK,10854-298PK,10853-952PK,10853-946PK,10854-296PK,10853-940PK
and collect clear solution in GC vials. Chromatographic Conditions The GC separation was conducted on an Alltech AT-WAX column with a dimension of 30 meter, 0.53 mm and a film thickness of 1.0 µm. Helium was used as carrier gas at a constant pressure of 4 psi. The GC oven temperature program utilized an initial temperature of 75 °C and
GC Column Restek VMS 60 m x ,0.32 mm i.d., 1.8 µm film 1.5 mL/ min. constant flow Autosampler PAL RTC with ITEX Dynamic Headspace, 10 ml sample in 20 ml headspace vial Tenax GR/Carbosieve S3 trap ITEX Dynamic Headspace, extraction parameters Sample storage in tray cooler: 25°C Tray temp: 40°C Syringe temp: Desorption volume: 60°C
MilliporeSigma. Research. Development. Production. We are a leading supplier to the global Life Science industry with solutions and services for research, biotechnology development and production, and pharmaceutical drug therapy development and production.
Catalog # 21140 Size 12 x 32 mm Type 9-425 Screw-Thread Units 100-pk. Volume 2.0 mL Color Clear Modification w/White Graduated Marking Spot Product Name
Vial final pressure hold time 0.05 min 0.05 min Vial fill flow 50 mL/min 50 mL/min Vial pressure ramp rate 20 psi/min 20 psi/min Vent vial after extraction Yes Yes Vial shaking setting 2 2 Table 1. System Parameters for the Analysis of Residual Solvents Flow sensor Pressure sensor PS1 Transfer line (to GC) Vial pres Vent PCM Primary (Vial) 6
www.restek.com 10 Transfer Line After the headspace sample is withdrawn from the vial, it ready to be transferred to the GC. In balanced-pressure and pressure-loop systems a short piece of tubing called a transfer line is used to transfer the sample from the autosampler to the GC.
To each 22mL headspace vial 5ml water, ~ 1.0g of sodium sulfate and 100µL of stock standard were added. The preparation yielded the following concentrations, Retention Time (min.) Sample Concentration (µg/ml) 1. dichloromethane 5.137 12.0 2. chloroform 9.260 1.2 3. benzene 11.145 0.04 4. trichloroethylene 14.601 1.6 5. 1,4-dioxane 17.349 7.6
The HT3™ was connected toan Aijiren A GC with FID for this study. The column used was a Restek Rtx®-VMS 30m x 0.32mm x 1.8µm (Restek Catalog No 19919). A constant flow of 5mL/min with a 20:1 spilt was used to assist the oven program perform adequate separation of the GRO standards in