How to Choose Right Syringe Filter -- Filter Membrane Materials

How to Choose Right Syringe Filter -- Filter Membrane Materials

Jan 08, 2017 · How to choose right syringe filter is important for filtration. In this blog we are going to talk about the membrane materials used for manufacturing syringe filters. Please check the filter membrane chemical compatibility for the liquids you are going to filter.

Send Inquiry           Chat Now
Defining a Pore Size and Sterile Filtering; 0.2 Micron vs. 0

Defining a Pore Size and Sterile Filtering; 0.2 Micron vs. 0

Jun 26, 2014 · After the discovery, researchers and labs competed to create the new filtration standard, arbitrarily defining their filters to be either 0.2 or 0.22 micron in pore size, roughly half the size of the old standard. What that means is, for the purpose of sterilization, 0.2 micron and 0.22 micron filters are indistinguishable.

Send Inquiry           Chat Now
Membrane Filtration - MRWA

Membrane Filtration - MRWA

Membrane Filtration 1 Membrane Filtration . A membrane is a thin layer of semi-permeable material that separates substances when a driving force is applied across the membrane. Membrane processes are increasingly used for removal of bacteria, microorganisms, particulates, and natural organic material, which can impart color,

Send Inquiry           Chat Now
NEW POSSIBILITIES IN FILTRATION

NEW POSSIBILITIES IN FILTRATION

Filter papers retain the impurities or particles of the liquid fluids on the surface as well as within the matrix of the filters. The particles or impurities are settled into the filter, modifying its filtration properties. Within the filter fibers arranged in an anarchic way into the filter paper, it creates a secondary filtration layer.

Send Inquiry           Chat Now
Glass Fiber Syringe Filter at Thomas Scientific

Glass Fiber Syringe Filter at Thomas Scientific

EZFlow 25mm High Particulate Syringe Filters are designed for high throughput filtration of viscous and particle-laden solutions. The syringe filter contains a filter membrane along with a glass fiber pre-filter. The filter membrane is available in PES or Hydrophilic PVDF materials, offered in 0.2µm.

Send Inquiry           Chat Now
Syringe Filters - SiliCycle

Syringe Filters - SiliCycle

Syringe filters are offered by SiliCycle to help scientists with their laboratory filtration needs. They are compatible either with aqueous, organic or inorganic solutions. SiliCycle Syringe Filters are available in a wide variety of membranes (Nylon, PTFE, PVDF, PES, and RC) with popypropylene housing. They are the perfect choice for many applications in the fields of environmental, pharmaceutical, biotechnological, forensic and food & beverage laboratories. SiliCycle Syringe Filters are specially designed to offer efficient and superior flow rate for any type of solution. These high quality products provide you with optimal filtration and particulate-free samples prior to injection. This extends apparatus lifetime which decreases overall analysis cost. See full list on silicycle.com Environmental Environmental analysis of water, waste water, soil and sludge can be easily filtered using the SiliCycle Syringe Filter portfolio. Pharmaceutical & Biotechnological At each step of the drug discovery process, API or target compounds have to be isolated, purified and filtered prior to analysis. SiliCycle Syringe Filters achieve easy purification of complex physiological matrices. Forensic Elimination of particulates before injection to a sub-micron device is necessary prior to each clinical or toxicological analysis (HPLC, GC or Mass Spectrometer). Food & beverage Improving the detection limits for pesticides, herbicides, flavours and fragrances analysis requires high quality syringe filter products because of the presence of different types of particulates in the samples. See full list on silicycle.com Loading Fill the syringe with the liquid sample and allow a small volume of air to enter the Syringe. This small volume of air is used as a purge to minimize fluid retention when expelling the liquid sample from the syringe. Assembly Twist the SiliCycle Syringe Filter Luer-Lok™ onto the syringe. Make sure that the Luer-Lok™ is matching with the syringe to prevent the filter from coming off during the filtration. Filtration Direct the SiliCycle Syringe Filter tip into the collection vessel and apply gentle pressure onto the syringe plunger. Push the liquid sample and the air volume through the SiliCycle Syringe Filter to maximize sample recovery. See full list on silicycle.com

Send Inquiry           Chat Now
Millex® Syringe Filters | Life Science Research | MilliporeSigma

Millex® Syringe Filters | Life Science Research | MilliporeSigma

Millex® Syringe filters set the standard for reliable small volume filtration (1 mL to 200 mL). Available in 4, 13, 25, 33, and 50 mm diameters. Minimal hold-up volume for less sample loss o f small volumes and are ideal for solutions such as antibiotics and tissue culture additives. Their unsurpassed quality and consistency of results has led

Send Inquiry           Chat Now
Quick Reference Guide Millex Syringe Filters

Quick Reference Guide Millex Syringe Filters

33 mm Millex filters have 20% more filter surface than 25 mm filters for significantly higher flow rate and throughput. Higher Operating Pressure With a maximum housing pressure of 150 psig (10 bar) solutions can be filtered faster. Low Extractables, Low Binding A variety of membranes and housings ensure chemical

Send Inquiry           Chat Now
Fritted Glass at Thomas Scientific

Fritted Glass at Thomas Scientific

Kemtech America. Filter Tube, Fritted, Glass Stopcocks, Synthware, Inner Joints: 14/20 or 24/40, Frit OD: Sizes available ranging from 30-36mm, Frit Porosity: Coarse or Medium, Stopcock Bore: 2mm, Stopcocks have constant pressure retention device. Related Products: Glass Frit Filters. Compare this item.

Send Inquiry           Chat Now
Filter Product Guides and Charts - Support

Filter Product Guides and Charts - Support

Filter Product Guides and Charts. General syringe Filter Selection Help Page. Regenereated Cellulose (RC), Cellulose Esters (MCE), Nylon and nylon low Ext., Polypropylene (PP), Glass Fiber, PVDF (polyvinylidene flouride) and PTFE Membrane. Chemical Compatibility for Membranes. Find out important compatibility information before you purchase.

Send Inquiry           Chat Now
PROPOR SG Filters - parker.com

PROPOR SG Filters - parker.com

10¨ (250 mm) fi lter cartridge. PROPOR SG Filters Protein binding on membrane materials 140 120 100 80 60 40 20 0 Protein Adsorption (mg / cm 2) Nylon Polypropylene Polysulphone PVDF Pdh PES Membrane Material HSA g-globulin Micron Rating 0.1 0.2 0.45 Insulin Filter Cartridges / MURUS / DEMICAP / Syringe FIlters

Send Inquiry           Chat Now
Millex® Syringe Filter Units, Sterile, 33mm - Sterile Syringe

Millex® Syringe Filter Units, Sterile, 33mm - Sterile Syringe

Millex-GP filters are recommended for sterile filtering protein solutions, tissue culture media, buffers and additives. Millex filters with Durapore® (PVDF) membrane are the lowest protein-binding syringe filters available. Use them to filter protein solutions. The 0.2 µm filters are sterilizing grade.

Send Inquiry           Chat Now
Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose

Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose

Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose esters, 33 mm, ethylene oxide sterilized Background Information Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas.

Send Inquiry           Chat Now
Solvent Compatibility Chart for Syringe Filters

Solvent Compatibility Chart for Syringe Filters

Syringe Filters Solvent Compatibility Chart 1 Protect any analytical system. 2 Extend LC column lifetime. 3 Achieve more reproducible analyses. 4 Variety of membranes, porosities, and diameters available. 5 Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure.