Home » News » Syringe Filter for Sale » Compare Nylon Syringe Filter for Sterile Filtration Turkey

Compare Nylon Syringe Filter for Sterile Filtration Turkey



Nylon Syringe Filter, syringe filter, HPLC sample preparation

Nylon Syringe Filter, syringe filter, HPLC sample preparation

MS ® Nylon syringe filters offer universal application for analytical procedures. Hydrophilic Nylon is ideal for aqueous (non-acidic) or organic sample prep and HPLC, GC or dissolution sample analysis. With its excellent flow characteristics, very low extractable levels and mechanical stability, Nylon offers the best combination of physical parameters to meet the most stringent analytical needs in 4mm, 13mm, 17mm, 25mm, 33mm diameters.

Send Inquiry           Chat Now
Syringe Filter China Trade,Buy China Direct From Syringe

Syringe Filter China Trade,Buy China Direct From Syringe

Tanvi syringe filters can be divided into disposable syringe filters and membrane replaced syringe filters. Add to Compare PVDF hydrophobic Pore size 0.22 laboratory syringe filters Lab Disposable pp Sterile nylon Syringe Filters manufacturer

Send Inquiry           Chat Now
Sterile Filtration & Clarification - Laboratory | Pall

Sterile Filtration & Clarification - Laboratory | Pall

Syringe filters rapidly filter small volume samples and are available with diameters of 13, 25, 32, or 37 mm. The Acrodisc sterile syringe filters are available with Supor (PES sterile filter) membrane featuring both a large EFA and PF (Pre Filter) to maximize throughput and flow rate for sterile filtration and clarification requirements.

Send Inquiry           Chat Now
Nylon filter | Sigma-Aldrich

Nylon filter | Sigma-Aldrich

Pricing. SLGNM25. 0.20 µm pore size, 25 mm diameter, Millex-GN Nylon membrane with glass fiber prefilter, hydrophilic, domed housing. Expand. Hide. SLHNM25. 0.45 µm pore size, 25 mm diameter, Millex-HN Nylon membrane with glass fiber prefilter, hydrophilic, domed housing.

Send Inquiry           Chat Now
Certified sterile PTFE membrane filter manufacturer-PTFE

Certified sterile PTFE membrane filter manufacturer-PTFE

Syringe Filter, Filter, Mbr Membrane manufacturer / supplier in China, offering FDA Standard PTFE Filter Membrane for Sterile Filtration 0.22 Micron SGS Test, Nylon/Pes/PVDF/PTFE Pleated Filter Cartridges Compatible with Millipore′ S Water System, Membrane Filter Buffer 0.2um 0.45 Micron Pes Filter Cartridge for Blood Serum and Biologicals and so on.

Send Inquiry           Chat Now
Membrane Filter Chemical Compatibility Chart

Membrane Filter Chemical Compatibility Chart

1) Syringe filter housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices. 2) Solutions at temperatures up to 100°C can be filtered using syringe filters. 3) Syringe filters can be sterilized by autoclave at 125°C for 15 minutes.

Send Inquiry           Chat Now
How to Select a Syringe Filter and How to Use it? (2020 Guide)

How to Select a Syringe Filter and How to Use it? (2020 Guide)

Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.

Send Inquiry           Chat Now
D13 Syringe Filters - D13 | Sterlitech

D13 Syringe Filters - D13 | Sterlitech

D13 Syringe Filters. These D13 Filter Capsules have been designed for simple, quick, and efficient filtration of fluids used in laboratory and analytical small-scale applications; 15 different media options can be placed in an all-polypropylene construction for excellent chemical compatibility. The small compact design of the filter capsule

Send Inquiry           Chat Now
Difference between hydrophilic and hydrophobic filters

Difference between hydrophilic and hydrophobic filters

Hydrophobic filters are best suited for gas filtration, low surface tension solvents, and venting. In certain applications, hydrophobic filters are used to filter aqueous solutions because of compatibility requirements. Water or aqueous solutions can also pass through a hydrophobic filter once the water breakthrough pressure is reached.

Send Inquiry           Chat Now
Advantec - Aurora Pro Sci

Advantec - Aurora Pro Sci

Advantec Nylon Syringe Filter, Non-Sterile. Nylon membrane is suitable for various applications from clarification to sterile filtration. The me.. $0.00. Add to Cart. Advantec Absorbent Pad. Cellulose pads 47 mm plain white discs fit into standard petri dishes. Routinely tested for absorpti.. $0.00.

Send Inquiry           Chat Now
Nylon Syringe Filters - Syringe Filters | Sterlitech

Nylon Syringe Filters - Syringe Filters | Sterlitech

Because of their low inherent levels of extractables, nylon membrane syringe filters are commonly used to filter samples that are intended for HPLC analysis. Nylon membrane syringe filters may not be suitable for all samples and are ideal for near neutral pH aqueous solutions and compatible nonaqueous solvents.

Send Inquiry           Chat Now
Eastchem Syringe Filter PES OFFer Hydrophilic Size 25mm D

Eastchem Syringe Filter PES OFFer Hydrophilic Size 25mm D

Scientific syringe filters offer universal application for analytical procedures.The membrane is suitable for the filtration of aqueous solutions and most mild organic solutions. Hydrophilic nylon is ideal for aqueous (non-acidic) or organic sample PREP and HPLC, GC or dissolution sample analysis.

Send Inquiry           Chat Now
The Lab Depot | Syringe Filters - Filtration

The Lab Depot | Syringe Filters - Filtration

Compare our sterile and non-sterile syringe filters to name brands such as Pall* Acrodisc* and Whatman Puradisc*. Polyamide/Nylon (PA) Hydrophilic Syringe Filters. Polytetrafluoroethylene (PTFE) Hydrophilic or Hydrophobic Syringe Filters. Polyvinylidene difluoride (PVDF) Hydrophobic Syringe Filters. Polyethersulfone (PES) Hydrophilic Syringe

Send Inquiry           Chat Now
DMSO-Safe Acrodisc® Syringe Filter | Pall Shop

DMSO-Safe Acrodisc® Syringe Filter | Pall Shop

Filter Media: Nylon; Housing: Polypropylene; Effective Filtration Area. 2.8 cm 2; Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Typical Hold-Up Volume (with air purge) < 50 μL; Maximum Operating Temperature. 55 °C (131 °F) Maximum Operating Pressure. 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate. 60 mL/min at 2.1 bar (210 kPa, 30 psi)

Send Inquiry           Chat Now
sterile filter, sterile filter Suppliers and Manufacturers at

sterile filter, sterile filter Suppliers and Manufacturers at

PVDF hydrophobic Pore size 0.22 laboratory syringe filters, Lab Disposable pp Sterile nylon Syringe Filters manufacturer. US $16.00-$30.00/ Bag. 1 Bag (Min. Order) CN Xi'an Tefic Biotech Co., Limited. 5 YRS. 68.2%. 3.8 ( 4) Contact Supplier. Add to Favorites.

Send Inquiry           Chat Now
Inquiry
Please contact us if you have questions or comments regarding Syringe Filter.
* Name:
* Email:
Tel:
Country:
* Content: