Home » News » Syringe Filter for Sale » How to Choose Right 13mm Syringe Filter for Sample Preparation

How to Choose Right 13mm Syringe Filter for Sample Preparation



13mm 0.22um Cellulose Acetate Syringe Filter For Preparation

13mm 0.22um Cellulose Acetate Syringe Filter For Preparation

13mm 0.22um Cellulose Acetate Syringe Filter For Preparation Of Aqueous Samples For Hplc , Find Complete Details about 13mm 0.22um Cellulose Acetate Syringe Filter For Preparation Of Aqueous Samples For Hplc,Sample Filter,Filtration,Filter Membrane from Other Lab Supplies Supplier or Manufacturer-Ningbo Excellent New Material Co., Ltd.

Send Inquiry           Chat Now
How to Choose a Membrane Filter - Sterlitech

How to Choose a Membrane Filter - Sterlitech

2. Decide an appropriate pore size. The pore size of a filter, stated in microns (aka micrometers or µm), is determined by the diameter of particles retained by the filter or by a bubble point test. • Nominal ratings are the pore size at which a particle of defined size will be retained with an efficiency below 100% (typically 90-98%)

Send Inquiry           Chat Now
13mm Nylon Syringe Filter--Aijiren Vials for HPLC/GC

13mm Nylon Syringe Filter--Aijiren Vials for HPLC/GC

Aijiren produces usually sizes of 13 mm and 25 mm. Each of them has a different ability to hold particles. According to the sample size, the appropriate filter diameter can be selected. For example, a diameter of 13 mm can be used for samples of 1-10 ml. Similarly, 25 mm PVDF syringe filters can be used for sample volumes of 10-100 ml.

Send Inquiry           Chat Now
VWR® Syringe Filters | VWR

VWR® Syringe Filters | VWR

Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common

Send Inquiry           Chat Now
Choosing the Best Syringe Filter for Your Application | Lab

Choosing the Best Syringe Filter for Your Application | Lab

Mar 17, 2020 · Sartorius. Labs use syringe filters for a variety of applications. These may include sterile filtration, sample preparation, and clarification of media additives, buffers, chemical reagents, drugs, and gases. Access this 3-step guide to selecting a filter suitable to your application, courtesy of Sartorius. CURRENT ISSUE - November 2021.

Send Inquiry           Chat Now
Filtration Products | Life Science Research | Merck Millipore

Filtration Products | Life Science Research | Merck Millipore

Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis. Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes

Send Inquiry           Chat Now
Whatman syringe filter and filter vial collection

Whatman syringe filter and filter vial collection

syringe filters. Features • 13 mm and 25 mm diameter syringe filters • 13 mm filters are recommended for samples up to 10 ml, and 25 mm filters for samples greater than 10 ml (however, the volume of sample that can be filtered through each filter depends on the characteristics of the sample) • Sterile options

Send Inquiry           Chat Now
Frequently Asked Questions: Sample Preparation

Frequently Asked Questions: Sample Preparation

To filter your sample, simply attach the appropriate syringe filter to the NORM-JECT and HENKE-JECT syringe and depress the plunger, capturing the effluent in a collection vial. Be sure to choose the correct volume syringe for the sample volume you wish to filter.

Send Inquiry           Chat Now
Sample Preparation for Ion Chromatography Comprehensive

Sample Preparation for Ion Chromatography Comprehensive

Dionex Sample Preparation Solutions • Off-line Syringe Filters • In-line AS-DV Autosampler Filters • In-line Filter Frit Cartridges Off-line OnGuard® II Cartridges • In-line InGuard® Cartridges • In-line IonPac® NG-1 Columns • 15 Anion IC and RFIC Concentrator Columns • 3 Cation IC and RFIC Columns

Send Inquiry           Chat Now
Filtration Products | Life Science Research | EMD Millipore

Filtration Products | Life Science Research | EMD Millipore

Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.

Send Inquiry           Chat Now
What type of syringe filter is suitable to purify extracted

What type of syringe filter is suitable to purify extracted

With HPLC, a 0.45 micron filter would be suitable. Please find two links to guides, for choosing filter materials. Fully agree witt Ade Kojore's recommendation. A 13 mm diameter 0,45 micron filter

Send Inquiry           Chat Now
Selection Guide Poster - Sartorius

Selection Guide Poster - Sartorius

Syringe Filters — Sartorius Minisart ® Selection Guide: How to Choose the Optimal Housing and Membrane Material for Your Application. Innovative design features, coupled with the largest surface areas and fastest flow rates make Minisart® syringe filters the ideal choice for all your syringe filtration needs.- -

Send Inquiry           Chat Now
Filtration Approaches to Sample Preparation and Cleanup

Filtration Approaches to Sample Preparation and Cleanup

Captiva Premium Syringe Filters Premium Syringe Filters Membrane Diameter / Pore size 4 mm 15 mm 25 mm (* 28 mm) 0.2 µm 0.45 µm 0.2 µm 0.45 µm 0.2 µm 0.45 µm PTFE ♦ ♦ ♦ ♦ ♦ ♦ Nylon ♦ ♦ ♦ ♦ PES ♦ ♦ ♦ ♦ ♦ ♦ Regenerated Cellulose ♦ ♦ ♦ ♦ ♦ ♦ Cellulose Acetate ♦ ♦

Send Inquiry           Chat Now
How to Choose Right Syringe Filter

How to Choose Right Syringe Filter

It is designed to be color-coding which makes the products more beautiful and innovative. The classic range is available in all of the major membranes including Nylon, PTFE, PVDF, CA and PES, which are supplied in 13mm, 25mm, 30mm formats in polypropylene housings. Applications. HPLC sample preparation. Routine QC analysis. Content uniformity

Send Inquiry           Chat Now
Whatman Syringe Filter Collection

Whatman Syringe Filter Collection

• 13 mm and 25 mm diameter syringe filters • 13 mm devices for samples up to 10 mL and 25 mm devices for samples greater than 10 mL (however, the volume of sample that can be filtered through each filter depends on the characteristics of the sample) • Sterile options • Pigment-free polypropylene housing • Unique prefiltration stack of

Send Inquiry           Chat Now
Inquiry
Please contact us if you have questions or comments regarding Syringe Filter.
* Name:
* Email:
Tel:
Country:
* Content: