Home » News » Syringe Filter for Sale » How to Choose Right PP Syringe Filter Filtration

How to Choose Right PP Syringe Filter Filtration



Sample Prep and Filtration: How to Select the Right Options

Sample Prep and Filtration: How to Select the Right Options

Captiva Premium Syringe Filters Premium Syringe Filters Membrane Diameter / Pore size 4 mm 15 mm 25 mm (* 28 mm) 0.2 µm 0.45 µm 0.2 µm 0.45 µm 0.2 µm 0.45 µm PTFE ♦ ♦ ♦ ♦ ♦ ♦ Nylon ♦ ♦ ♦ ♦ PES ♦ ♦ ♦ ♦ ♦ ♦ Regenerated Cellulose ♦ ♦ ♦ ♦ ♦ ♦ Cellulose Acetate ♦ ♦

Send Inquiry           Chat Now
Syringe Filters | Thermo Fisher Scientific - ES

Syringe Filters | Thermo Fisher Scientific - ES

Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.

Send Inquiry           Chat Now
Titan3 and Target2 Chromatography Syringe Filters

Titan3 and Target2 Chromatography Syringe Filters

Syringe filter unit specification Titan3 Target2 4 mm 17 mm 30 mm 4 mm 17 mm 30 mm Housing Polypropylene with integral colour-coded sealing ring Polypropylene with integral colour-coded sealing ring Polypropylene with integral colour-coded sealing ring Polypropylene Polypropylene Polypropylene Filtration area 0.125 cm2 1.6 cm2 4.9 cm2 0.125 cm2

Send Inquiry           Chat Now
Know More about Some Basic Methods To Using A Syringe filter

Know More about Some Basic Methods To Using A Syringe filter

Oct 01, 2021 · Simsii, Inc. is a leading individual supplier of lab filtration, including syringe filters, membrane filters, glass fiber syringe filters, and more. Our team consists of professionals experts who are committed to giving the guidance and support available. We will be delighted to help you. For Buying different types of filters! Visit our website.

Send Inquiry           Chat Now
Membrane filtration: A guide to choosing membranes | Cytiva

Membrane filtration: A guide to choosing membranes | Cytiva

Aug 07, 2018 · Polypropylene (PP) Membrane. Available in a membrane and non-woven formats, polypropylene is slightly hydrophobic and resistant to a broad range of chemicals and temperatures. When should you use it? DO USE: for aggressive filtration applications and solvents such as butyl alcohol, DMSO, methanol, and sodium hydroxide.

Send Inquiry           Chat Now
Blog - How to Choose the Right Type of Nylon Syringe Filters

Blog - How to Choose the Right Type of Nylon Syringe Filters

Jun 11, 2018 · Step Three – Select Correct Filter Area for Right Throughput And Optimization Of Flow Rate. You need to select Nylon Syringe filters with right filter area size that will ensure you have enough volume capacity and throughput to process your sample efficiently and quickly. This can be easily determined by the surface area of the membrane filter.

Send Inquiry           Chat Now
Corning Filtration Guide

Corning Filtration Guide

Polypropylene (PP) is used in the Spin-X® centrifuge filters and some of the syringe and disc filter housings. This plastic polymer has very good resistance to many solvents, refer to Table 3 for more chemical compatibility information.

Send Inquiry           Chat Now
How To Choose a Syringe Filter - Chrom Tech

How To Choose a Syringe Filter - Chrom Tech

Dec 07, 2020 · Syringe filters are made from a virgin polypropylene housing with a female luer lock inlet and a male slip luer outlet. To use syringe filters, the sample is loaded into a disposable luer syringe. The syringe is then attached to the female luer portion of the syringe filter by securely fastening with a twisting motion.

Send Inquiry           Chat Now
Filtration Media Selection Guide - Membrane filters, syringe

Filtration Media Selection Guide - Membrane filters, syringe

PP membranes are also well suited for biological sample filtration. View Polypropylene Membrane Filters View Polypropylene Syringe Filters. Glass Fiber. Glass fiber filter papers are commonly used as pre-filters in many filtration devices and for filtration of viscous or otherwise hard-to-filter samples with high solids content.

Send Inquiry           Chat Now
Do You Know How To Choose A Membrane Filter - Hawach

Do You Know How To Choose A Membrane Filter - Hawach

Mar 12, 2020 · 4. When selecting a syringe filter. In addition to the above factors, consider the sample size (that is, the size of the syringe filter to choose): usually, if the sample size is less than 2ml, a miniature filter head with a diameter of 4mm should be selected. The sample size is between 2 and 10ml, and a filter head with a diameter of 13mm is

Send Inquiry           Chat Now
13mm and 25mm Polypropylene GD/X, Syringe Filters, Disposable

13mm and 25mm Polypropylene GD/X, Syringe Filters, Disposable

Choose the 13mm size 13mm and 25mm Polypropylene GD/X, Syringe Filters, Disposable, Cytiva Whatman - Filters - D-F - Products JavaScript seems to be disabled in your browser.

Send Inquiry           Chat Now
The Best-selling biomed scientific sterile syringe filters

The Best-selling biomed scientific sterile syringe filters

The type of biomed scientific sterile syringe filters product after-sale service depends on what you need. A good general rule is that if your initial purchase was covered by warranty, then the company will provide free replacement parts for at least a year but often indefinitely depending on their policies and procedures as well as how quickly they respond in emergencies.

Send Inquiry           Chat Now
How to choose the correct syringe filter - Biomall Blog

How to choose the correct syringe filter - Biomall Blog

Oct 02, 2019 · The smaller the pore size, the more the pressure required to pass the sample through the syringe membrane filter. Filter Diameter: Syringe filter diameter depends upon the volume of the sample to be filtered. If the volume of the aqueous sample is Higher, the filter should be with a larger diameter. Syringe filters are available in a variety of diameters including 4mm, 13mm, 17mm, 20mm, 25mm, 30mm, and 33mm.

Send Inquiry           Chat Now
How to Choose a Membrane Filter

How to Choose a Membrane Filter

2. Decide an appropriate pore size. The pore size of a filter, stated in microns (aka micrometers or µm), is determined by the diameter of particles retained by the filter or by a bubble point test. • Nominal ratings are the pore size at which a particle of defined size will be retained with an efficiency below 100% (typically 90-98%)

Send Inquiry           Chat Now
Syringe Filters | Thermo Fisher Scientific - US

Syringe Filters | Thermo Fisher Scientific - US

Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.

Send Inquiry           Chat Now
Inquiry
Please contact us if you have questions or comments regarding Syringe Filter.
* Name:
* Email:
Tel:
Country:
* Content: