The Swinnex® line of syringe filter holders are used to ultraclean or sterilize small volumes of liquids dispensed by syringe. Connect the Swinnex® 13 mm filter holder with tubing to pressurized reservoir or automatic filling machine for filtering larger volumes.
Bottle Tops and Filter Units Extraction Thimbles Filter Holders and Hardware Filter Paper Filtering Funnels Food and Beverage Testing Glass Fiber Filters and Prefilters Membranes for Filtration Syringe and Syringeless Filters Water Testing and Environmental
2) Secure the filled syringe to the FLL inlet of the syringe filter with a 3) With the outlet pointed upward, gradually apply thumb pressure to the syringe plunger to initiate flow. 4) Continue thumb pressure until all the air in the device is displaced with liquid. 5)
Hawach sterile CA syringe filters autoclave at 121°C at 1 bar for 20 minutes/EO/Gamma. Each syringe filter is individually packaged and suitable for high sterilization requirements. CA syringe filter made from cellulose acetate membrane, which has many characteristics suitable for use as an enzyme carrier and latex particle encapsulation analysis
Designed for sterilizing and clarifying sterile solutions. Millex™ Sterile Syringe Filters: MCE Membrane are ready-to-use, syringe-driven units that have never been touched by human hands during filter assembly. Feature 0.22, 0.45 and 0.80µm pore sizes; medical-grade filters available. Pricing and
5 1 Syringe Filter Information 5 Using Syringe Filters 15 mm (ultrasonic welded) Housing Material Polypropylene Total Filter Volume 0.335 ml Dead Volume < 25 µm Filter Area177 mm2 Max Op. Pressure 7 Bar InletLuer-Lock (female) OutletLuer-Slip (male) 25 mm (ultrasonic welded)
Benefits • Versatile: Use for any application requiring a chemically resistant, hydrophilic, low protein-binding membrane • Documented batch-to-batch quality and consistency ensure reproducible results • 13 mm diameter with Mini-Tip outlet is ideal for filtration
To maximize filtration throughput, use the largest pore size filter that will provide the required purity. To extend filter life, use low flow rates or pressures. Air locks Air locks can seriously limit flow rates. To eliminate, point the outlet of the filter device upward during
2008/12/15 · How to use a Syringe Filter for embryo handling. This syringe filter has a low protein binding membrane to maximize recovery of critical components. Gamma
13mm. <100ml. 25mm. Step 3: Choose the suitable pore size based on the nature of your sample. Removal of high particulate matter with a pre filter is critical before any drug, toxic, or dirty environmental sample is filtered to ensure the highest syringe filter membrane performance.
Browse Pall shop for the Acrodisc® 13 mm syringe filter with a 10 mL/min flow rate at 2.1 bar (210 kPa, 30 psi). These nylon membrane syringe filters assure smooth operation and save time -
Figure 3. Filtration recovery comparison of the Aijiren Captiva Premium PES syringe filter with PVDF syringe filters for myoglobin samples at different concentrations. D: Dimer, M: Monomer. 0 20 40 60 80 100 120 Aijiren PES filter PVDF filter A PVDF filter B F i l
13mm Syringe Filter Housing material: Medical Polypropylene Filtration ares : 0.8cm² Process Volume:10 mL Hold-up volume : <15 ul Pressure Bar (PSI) : 7bar(100psi) Highest Temp. : 45 C Product 4mm Syringe Filter Product Specifications
13mm welded PTFE Hydrophilic syringe filter Material of housing : PP Effective filtration area (cm²) : 1.13cm² Pore size (um) : 0.22 / 0.45 Process volume(ml) : <10ml Maximum Operating Temperature : 130 Maximum Operating Pressure(psi) : 87psi
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and