Home » News » Syringe Filter for Sale » How to use 13mm Syringe Filter for Sterile Filtration

How to use 13mm Syringe Filter for Sterile Filtration



Syringe Filters - Pall Shop

Syringe Filters - Pall Shop

Pall Laboratory sterile-syringe filters meet the challenges of sterile applications: Gamma-irradiated, sterile packaging. Ergonomic, individually blister packaged. Dual-layer membrane with integrated pre-filter for high dirt-holding capacity and improved filterability. Low back pressure for ease of use.

Send Inquiry           Chat Now
Minisart® Syringe Filters | Sterile Filtration | Sartorius

Minisart® Syringe Filters | Sterile Filtration | Sartorius

Sartolab® Disposable Sterile Filter Systems and Bottle Top Filters are designed for the vacuum filtration of tissue culture media and components, biological fluids, and other aqueous solutions. The Sartolab® disposable 150 mL, 250 mL, 500 mL and 1000 mL bottles are designed as storage containers for sterile media, buffers, or other aqueous solutions.

Send Inquiry           Chat Now
Syringe Filter – Buy Lab Equipment Online | LabQuip

Syringe Filter – Buy Lab Equipment Online | LabQuip

How To Use a Syringe Filter Once you've chosen the right filter for what you're doing, draw your sample into the syringe and attach the filter to the output end. Make sure the filter is secured properly and push the syringe to release a small amount of liquid, ensuring all air is out of the syringe.

Send Inquiry           Chat Now
How to Select a Syringe Filter and How to Use it? (2020

How to Select a Syringe Filter and How to Use it? (2020

Note: The individually packed sterile syringe filter can be held in the original package to minimize contamination while attaching the syringe. Step 3: Secure the Syringe Filter Secure the syringe filter using a clockwise motion with luer-lock syringe.

Send Inquiry           Chat Now
Sterile Syringe Filter at Thomas Scientific

Sterile Syringe Filter at Thomas Scientific

Syringe Filter, Nylon, 0.45µm, 13mm Diameter. Denville. luer-lock syringe and are color-coded for easy recognition. The 30mm syringe filters can filter up to 100mL of sample with a retention volume of less than 100µL. The 13mm filters can filter 5 to 10mL of sample and have a retention volume of only 28µL.

Send Inquiry           Chat Now
Air Vent Filters Sterile Syringe Filters

Air Vent Filters Sterile Syringe Filters

13mm Syringe Filter Housing material: Medical Polypropylene Filtration ares : 0.8cm² Process Volume:10 mL Hold-up volume : <15 ul Pressure Bar (PSI) : 7bar(100psi) Highest Temp. : 45 C Product 4mm Syringe Filter Product Specifications

Send Inquiry           Chat Now
More Than 100ml High Throughput Sterile PES Syringe

More Than 100ml High Throughput Sterile PES Syringe

Regardless of the membrane filter material, always use a 0.22 μm pore size membrane filter as the final filter for any sterilizing filtration. How to choose Filter size 0-10ml Sample Volume use 13mm Syringe Filters; 10-100ml Sample Volume use 25mm Syringe

Send Inquiry           Chat Now
Syringe and Syringeless Filters | Fisher Scientific

Syringe and Syringeless Filters | Fisher Scientific

Bottle Tops and Filter Units Extraction Thimbles Filter Holders and Hardware Filter Paper Filtering Funnels Food and Beverage Testing Glass Fiber Filters and Prefilters Membranes for Filtration Syringe and Syringeless Filters Water Testing and Environmental

Send Inquiry           Chat Now
Bioyfil™ syringe filters-BioFil™ Syringe Filter-Syringe

Bioyfil™ syringe filters-BioFil™ Syringe Filter-Syringe

13mm. <100ml. 25mm. Step 3: Choose the suitable pore size based on the nature of your sample. Removal of high particulate matter with a pre filter is critical before any drug, toxic, or dirty environmental sample is filtered to ensure the highest syringe filter membrane performance.

Send Inquiry           Chat Now
Syringe Filter - 0.22 μm - PTFE Sizes: 13 mm & 25 mm |

Syringe Filter - 0.22 μm - PTFE Sizes: 13 mm & 25 mm |

Size. Available in both 13mm and 25mm diameters. These autoclavable 0.22 µm micron syringe filters are made out of a hydrophobic PTFE and are 100% reusable. They are perfect for inserting into liquid culture jar lids to provide contaminant-free gas exchange.

Send Inquiry           Chat Now
Syringe Filters for Sterile Filtration | Minisart® | Sartorius

Syringe Filters for Sterile Filtration | Minisart® | Sartorius

The effective filtration area of 6.2 cm2 for fastest filtration is the biggest amongst premium syringe filters. Minisart® with acrylic-based housing can be sterilized by ethylene oxide (EO) or gamma irradiation and are suitable for adhesive attachment and assembly to tubing making it easily user configurable to almost any setup.

Send Inquiry           Chat Now
Swinnex, polypropylene, 13mm Filter Holder (5/Pk) -

Swinnex, polypropylene, 13mm Filter Holder (5/Pk) -

The Swinnex® line of syringe filter holders are used to ultraclean or sterilize small volumes of liquids dispensed by syringe. Connect the Swinnex® 13 mm filter holder with tubing to pressurized reservoir or automatic filling machine for filtering larger volumes.

Send Inquiry           Chat Now
How to Choose Right Syringe Filter -- Filter Membrane

How to Choose Right Syringe Filter -- Filter Membrane

Use with: Heavily contaminated samples. Don’t use with: Benzyl alcohol. Sterilization: Syringe filters can be sterilized by autoclave at 125° for 15 minutes. Applications: Dissolution testing, filtration of high particulate samples, air filtration, recovery of DNA from biological samples.

Send Inquiry           Chat Now
Syringe Filters for Sterile Filtration |

Syringe Filters for Sterile Filtration |

Sterile filtration is the optimal method to reliably remove all microorganisms and particles for sterilization of liquids such as antibiotic, tissue culture additives and so on. Porayfilter can provide syringe filters designed for sterile filtration.

Send Inquiry           Chat Now
China Sterile Syringe Filter Manufacturers - Sterile

China Sterile Syringe Filter Manufacturers - Sterile

13mm 0.45/0.22um Hydrophilic PTFE Sterile Syringe Filter For Lab Use. Product description: PTFE syringe filter provides high flow rate, best chemical compatibility and low protein binding, ideal for aqueous solutions and solvents filtration, especially aggressive solvent as well as air filtration. Application : In addition to HPLC, syringe

Send Inquiry           Chat Now
Inquiry
Please contact us if you have questions or comments regarding Syringe Filter.
* Name:
* Email:
Tel:
Country:
* Content: