Home » News » Syringe Filter for Sale » How to use 45mm Syringe Filter for Sterile Filtration

How to use 45mm Syringe Filter for Sterile Filtration



Nalgene™ Syringe Filters, Non-sterile

Nalgene™ Syringe Filters, Non-sterile

Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.

Send Inquiry           Chat Now
Pall Acrodisc Syringe Filters

Pall Acrodisc Syringe Filters

filtration area (EFA) in a 25 mm filter — 30% more than traditional 25 mm syringe filters. Our non-sterile syringe filters offer the following advantages: Extend UHPLC column life over 100 times compared to an unfiltered sample Protect expensive instrument detectors and columns Contribute minimal extractable material

Send Inquiry           Chat Now
Sterile Millex® Syringe Filters for Liquid and Air

Sterile Millex® Syringe Filters for Liquid and Air

Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex ® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex ® filters not only feature minimal hold-up

Send Inquiry           Chat Now
Corning Filtration Guide

Corning Filtration Guide

Syringe/Disc Filters The smaller conventional Corning® syringe disc-type filters (4, 15, 25, 26, and 28 mm diameter) are used with syringes which serves as both the fluid reservoir and the pressure source. They are 100% integrity tested. The HPLC-certified non-sterile syringe filters are available with nylon, regenerated

Send Inquiry           Chat Now
Whatman™ Uniflo™ Syringe Filters | Cytiva

Whatman™ Uniflo™ Syringe Filters | Cytiva

Whatman™ Uniflo™ Syringe Filters are disposable filter units designed to provide clean filtrate from small volumes up to 100 mL. They are available in a variety of membrane choices with a polypropylene overmold housing, and include both sterile and non-sterile options. 13 mm, 25 mm or 30 mm diameters. 0.2 μm or 0.45 μm pore sizes.

Send Inquiry           Chat Now
Syringe Filters

Syringe Filters

High performance sterile and nonsterile syringe filters offered in a variety of membrane materials and pore sizes, tailored for sample preparation for HPLC, UHPLC, ion chromatography, dissolution testing, and other analyses.

Send Inquiry           Chat Now
How to Use a Syringe Filter - YouTube

How to Use a Syringe Filter - YouTube

How to use a Syringe Filter for embryo handling. This syringe filter has a low protein binding membrane to maximize recovery of critical components. Gamma

Send Inquiry           Chat Now
Syringe Filters - Sigma-Aldrich

Syringe Filters - Sigma-Aldrich

Syringe filters are single-use, membrane-based devices used for the removal of particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. Proper filtration of samples improves the quality and consistency of analytical results and decreases

Send Inquiry           Chat Now
Nalgene™ Sterile Syringe Filters - Thermo Fisher Scientific

Nalgene™ Sterile Syringe Filters - Thermo Fisher Scientific

Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.

Send Inquiry           Chat Now
Blog - A Guide to Syringe Filters and How to Use Them

Blog - A Guide to Syringe Filters and How to Use Them

Mar 04, 2018 · 1.Get the most appropriate filter to use. 2.Draw 1ml of air followed by your sample in a sterile syringe. 3.Eject 1ml of the sample in a waste container. 4.Eject the rest of the sample in a clean vial for storage. 5.Push the air you initially drew into the same vial. This step will push out the remaining fluid and will reduce the held up volume.

Send Inquiry           Chat Now
Understanding syringe filters - Andy Connelly

Understanding syringe filters - Andy Connelly

Sep 28, 2016 · Press the syringe plunger gently to push sample through the filter. If possible, discard the first 0.25-0.5ml of sample because if there is any contamination present, it is likely to be higher in those first few microlitres of sample. If the back pressure ever increases significantly, change the filter as it may have plugged.

Send Inquiry           Chat Now
Syringe filters for use from medical devices to cell

Syringe filters for use from medical devices to cell

Over 120 different syringe filter product codes offer one of the most diverse options for meeting users’ application needs, from medical device sterile filtration to research use cell culture

Send Inquiry           Chat Now
Syringe Filters | Corning

Syringe Filters | Corning

A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%

Send Inquiry           Chat Now
Syringe Filters - Pall

Syringe Filters - Pall

Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size.

Send Inquiry           Chat Now
How to Use Syringe Filter - Hawach

How to Use Syringe Filter - Hawach

Feb 10, 2022 · Precautions for using syringe filters 1. Do not use a syringe filter smaller than 10 cc, because the small-volume column tube may cause the pressure to exceed the upper limit, resulting in damage to the filter membrane or personal injury. 2. Only for laboratory use, one-time use, non-renewable. 3. The filtrate at the beginning should be discarded.

Send Inquiry           Chat Now
Inquiry
Please contact us if you have questions or comments regarding Syringe Filter.
* Name:
* Email:
Tel:
Country:
* Content: