These Corning® syringe filters have acrylic copolymer housings, female Luer lock inlets and male Luer slip outlets. Polyethersulfone (PES) membranes provide the fastest flow rates, low protein binding and low extractables 100% integrity tested, sterile and
Regenerated Cellulose syringe filters are used for low nonspecific binding applications, as well as tissue culture media filtration and general biological sample filtration. They have strong resistance to standard aqueous and organic HPLC solvents such as acetonitrile or methanol and so recommended for UHPLC / HPLC sample preparation and DMSO compatibility.
Syringe Filters with High Flow Rates and Low Protein Binding 0.2 µm, 25 mm (50/pkg). Superior flow rates and higher throughputs than competitive devices., Pall Acrodisc Syringe Filters with Supor Membrane, Sterile Filtration, 25 mm (50/pkg) “Pall Laboratory
Sartolab® Disposable Sterile Filter Systems and Bottle Top Filters are designed for the vacuum filtration of tissue culture media and components, biological fluids, and other aqueous solutions. The Sartolab® disposable 150 mL, 250 mL, 500 mL and 1000 mL bottles are designed as storage containers for sterile media, buffers, or other aqueous solutions.
Sartorius Minisart® syringe filters are the No. 1 choice for sterile filtration, analytical sample preparation, and clarification of media additives, buffers, chemical reagents, drugs and even gases! Innovative design features, coupled with the largest surface areas and
SAMP2HNNB This 33 mm syringe filter with a Hydrophilic Nylon membrane, for non-sterile filtration on the Samplicity G2 system, has a 0.45 µm pore size used in preparation of aqueous & organic solutions prior to chromatography or other instrument analyses.
Ready-to-use units, which offer flow rates at low inlet pressures, allow for a correspondingly rapid sterile filtration. Colour: Dark blue Filter diameter: 28 mm Filtration area: 6,2 cm² Hold-up volume: 0,15 ml Maximum Pressure: 4,5 bar Max. temperature: 50 C
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated
Syringe filters must also have low protein binding to ensure proteins are not retained in the filter. Sample Clean-Up, Virus Filtration, and Mycoplasma Reduction Laboratories need a wide range of membrane types and pore sizes for all varieties of sample clean-up, cell debris removal, virus filtration, or general filtration purposes.
Syringe-driven Filter Unit Background Information Overview of Non-Sterile Millex® Syringe Filters with Hydrophilic PTFE • Lowest extractables, optimizing background levels of sensitive analyses like UHPLC and LC-MS • Filtration of protein-containing solutions
Sterile or Non-Sterile Syringe Filters While the primary function of a syringe filter is to remove particulates from a liquid sample, you will select either a sterile or non-sterile filter, depending on the end application. Sterile syringe filters are used to sterilize non-sterile
Minisart ® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17574 with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version Q is a non-sterile bulk
10 Pack Syringe Filter Sterile PES Hydrophilic Filtration 0.22um Pore Size, 33mm Membrane Diameter Sterile PES Membrane Individually Packed by Membrane Solutions 4.6 out of 5 stars 287 $13.99 $ 13 .
Minisart ® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17762 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet.
Millex Sterile syringe filter units are available in a larger 33mm housing with either MCE, PVDF or PES membranes. - Find MSDS or SDS, a COA, data sheets and more information. *Medical Millex filter units (M33 catalogue numbers) should only be used in the U